1. Introduction
→ Used in compression test for concrete drainage pipes (ID ≤2600mm), reinforced concrete drainage pipes, etc.
→Used for rainwater pipes, sewage pipes, farm irrigation pipes, gravity flow pipes, slotting and jacking construction pipes and other pipes for other application, and also for some pipes produced by adopting centrifuge, vertical extrusion and other technology.
→Comply with standards EN1916, ASTM C497, ASTM C301
2. Technical Specification
No. |
Items |
YAW-1000P |
1 |
Max. load |
1000kN |
2 |
relative error of indicating value |
≤±1% of indicating value |
3 |
measuring range of load |
5%~100% Full scale |
4 |
load resolution |
1/300000 |
5 |
loading rate |
600N/s~60kN/s |
6 |
pistion stroke |
400mm |
7 |
distance between upper and lower platens |
≥2450mm |
8 |
Test space |
3000mm |
9 |
span between columns |
3000mm |
10 |
loading mode |
Manual control, hydraulic loading |
11 |
working voltage |
380V±10% 50Hz |
12 |
motor power |
3.0 kW |
13 |
Dimension of loading frame(L*W*H) |
Approx. 3700x2500x6900mm |
14 |
Dimension of control system (L*W*H) |
660x580x1210mm |