1. Introduction
→used in static compression test for various manhole cover,trench cover,well grates/shutter grates.
→used in bearing capacity test of frame and residual deformation test for various manhole cover,trench cover,well grates/shutter grates.
→used for manhole cover loading test, displacement deformation test, strain test, compression cyclic test,etc.
→used for crack load test,break load test,residual deformation test,crack width test,etc.
→used in compression strength and bending strength tests for concrete,construction member,tubular piles,construction materials,etc.
→used in compression strength and bending strength tests for metals, nonmetals and composites, etc.
Test Standards
→BS EN 124:2015 Gully tops and manhole tops for vehicular and pedestrian areas
→Part1: Definitions, classification , general principles of design, performance requirements and test methods
→Part2: Gully tops and manhole tops made of cast iron
→Part3: Gully tops and manhole tops made of steel or aluminium alloys
→Part4: Gully tops and manhole tops made of steel reinforced concrete
→Part5: Gully tops and manhole tops made of composite materials
→Part6: Gully tops and manhole tops made of polypropylene (PP), polyethylene (PE) or unplasticized poly (vinyl chloride) (PVC-U)
2. Technical Specification
MCCT1000/1500 Manhole Cover Compression Testing Machine (EN124) (USA/NA) |
|||
1 |
Max. Load capacity |
1000kN |
1500kN |
2 |
Relative error of indicating value of load |
≤±1% |
|
3 |
Measuring range of load |
1%-100% |
|
4 |
Load resolution |
1/±300000F.S |
|
5 |
Constant rate stress range |
2~60 N/mm2·S-1 |
|
6 |
Stress rate error |
≤±1% |
|
7 |
Constant rate strain range |
0.00025/s~0.0025/s |
|
8 |
Strain rate error |
≤±1% |
|
9 |
Measuring range of deformation |
0-350mm |
|
10 |
Residual deformation measurement |
0.001mm |
|
11 |
Loading speed |
0.02%~2%FS/s |
|
12 |
Compression test space |
0-350mm |
|
13 |
Test space (L*W) |
1500mm*1500mm |
|
14 |
Spherical stiffness cushion block |
Φ250x40mm;Φ356x40mm |
|
15 |
Piston stroke |
200mm |
|
16 |
Motor power |
3.0kW |
4.0kW |
17 |
Working voltage |
American 440VAC, 60Hz |
|
18 |
Dimension of loading frame (L*W*H) |
≈1700x1500x2300mm |
≈1800x1500x2400mm |
19 |
Dimension of control cabinet (L*W*H) |
1200*800*1100mm |